sandboxes/demo_en/corpus/001-timber-frame-intro-simul.txt view on Meta::CPAN
lambda = thermal conductivity in W/(m·K)
Minimum R required by climate zone:
- Zone A (highland / severe cold) : R_min = 6.5 m²·K/W
- Zone B (temperate) : R_min = 4.5 m²·K/W
- Zone C (mild â coastal south) : R_min = 3.5 m²·K/W
Typical conductivity values:
- Mineral wool 035 : lambda = 0.035 W/(m·K)
- Mineral wool 040 : lambda = 0.040 W/(m·K)
- Rigid PIR 022 : lambda = 0.022 W/(m·K)
§4.2 â Vapour control layer: minimum Sd value (BS 5250 / BS EN ISO 13788)
The vapour control layer must provide sufficient resistance to vapour
diffusion (Sd value) according to the service class:
- Service class 1 (dry interior) : Sd ⥠5 m
- Service class 2 (humid interior) : Sd ⥠18 m
- Service class 3 (very humid) : Sd ⥠50 m
Any vapour control layer with Sd below the required minimum is NON-COMPLIANT.
=============================================================================