App-Netsync

 view release on metacpan or  search on metacpan

share/mib/CISCO-STACK-MIB.my  view on Meta::CPAN

                 'arpInspectionRate' and 'noStaticInlinePwr'.

                 Modified Description clause for deprecated objects:
                 sysIpAddr, sysNetMask, sysBroadcast, sysReset,
                 sysConsolePrimaryLoginAuthentication,
                 sysConsolePrimaryEnableAuthentication,
                 sysTelnetPrimaryLoginAuthentication,
                 sysTelnetPrimaryEnableAuthentication,
                 sysPortFastBpduGuard, chassisSerialNumber,
                 chassisComponentTable, moduleSerialNumber,
                 moduleHwHiVersion, moduleHwLoVersion,
                 moduleFwHiVersion, moduleFwLoVersion,
                 moduleSwHiVersion, moduleSwLoVersion,
                 portSpantreeFastStart, monitorGrp and
                 vlanSpantreeEnable.

                 Added new conformance Groups:
                 systemMiscGroup1,
                 systemTrapGroup1,
                 optionalSystemMiscGroup6,
                 optionalChassisGroup1,
                 portGroup4,
                 vlanGroup2,
                 ipPermitGroup2 and
                 optionalPortGroup1."

        REVISION "200305290000Z"
        DESCRIPTION
                "Change the ORGANIZATION clause. Deprecated
                 sysClearMacTime object."
        REVISION
                "200305050000Z"
        DESCRIPTION
                "Add support of the following objects: cisco7613sysID,
                 wsc6509nebasysID. ChassisType: wsc4507, wsc6509NEBA,
                 wsc65509, cisco7613. chassisPs1Type: pwr950dc,
                 pwr1900ac, pwr1900dc, wscac3000w,
                 pwrc451400dcp, wscdc3000w, pwr1400ac.
                 chassisPs2Type: pwr950dc, pwr1900ac, pwr1900dc,
                 wscac3000w,  wscdc3000w, pwr1400ac.
                 moduleTable: wsSvcIdsm2, wsSvcFwm1, wsSvcCe1,
                 wssvcSsl1, osm2oc12PosMMPlus, osm2oc12PosSIPlus,
                 osm16oc3PosSIPlus, osm1oc48PosSSPlus,osm1oc48PosSIPlus,
                 osm1oc48PosSLPlus, osm4oc3PosSIPlus, osm8oc3PosSIPlus,
                 osm4oc12PosSIPlus, wsx6548getx, wssup720, wssup720base.
                 moduleSubType: wsf6kpfc2a, wsf6kdfca, vsp300dfc,
                 wsf6kpfc3a, wsf6kdfc3a. moduleSubType2: wsg6489,
                 wsg6485, wsu4502gb, wssvcidsupg, wssup720.
                 portType: e100BaseLX.

                 Deprecate the following objects: sysIpAddr, sysNetMask,
                 sysBroadcast, sysTrapReceiverTable, sysReset,
                 sysClearPortTime, sysClearMacTime,
                 sysPortFastBpduGuard, chassisComponentTable,
                 portSpantreeFastStart, vlanTable, portChannelTable.

                 Remove the TC MacAddressType, and replaced other uses
                 by MacAddress."

        REVISION
                "200209240000Z"
        DESCRIPTION
                "Added more HW models."
        REVISION
                "200106110000Z"
        DESCRIPTION
                "Added cat6000 new HW chassis & modules."
        REVISION
                "200104110000Z"
        DESCRIPTION
                "Added more HW modules;
                 Added the following MIB objects under systemGrp:
                        sysMaxRmonMemory
                        sysMacReductionAdminEnable
                        sysMacReductionOperEnable
                 Added the following MIB object under fileCopyGrp:
                        fileCopyRuntimeConfigPart
                 Added the following MIB object under filterPortTable:
                        filterPortSuppressionOption
                 Added the following MIB object under syslogGrp:
                        syslogTelnetEnable"

        REVISION
                "200010100000Z"
        DESCRIPTION
                "Added more HW modules;
                 Added the following objects in systemGrp
                     sshPublicKeySize
                 Added the vlanTrunkMappingTable in vlanGrp
                 Added portJumboFrameGrp
                 Added the following objects in portCpbTable:
                        portCpbCosRewrite
                        portCpbTosRewrite
                        portCpbCopsGrouping
                 Added copyTechReportFromRuntimeToHost in fileCopyAction
                 Added ssh(2) in ipPermitAccessType &
                 ipPermitDeniedAccess."

        REVISION
                "200005160000Z"
        DESCRIPTION
                "Added more HW models;
                 Added the following objects:
                        portInlinePowerDetect
                        vlanPortAuxiliaryVlan
                        portCpbInlinePower
                        portCpbAuxiliaryVlan
                        moduleAdditionalStatus
                        sysExtendedRmonNetflowModuleMask
                 Added the voiceGrp
                 Added the switchAccelerationGrp"

        REVISION
                "200002020000Z"
        DESCRIPTION
                "Added the following objects:
                        sysPortFastBpduGuard
                        sysErrDisableTimeoutEnable
                        sysErrDisableTimeoutInterval
                        sysTrafficMonitorHighWaterMark
                        chassisPs3Type

share/mib/CISCO-STACK-MIB.my  view on Meta::CPAN

        SYNTAX        INTEGER {
                          other(1),       -- none of the following
                          dualAttach(2),  -- port 1 is A and port 2 is B
                          singleAttach(3),-- port 1 is S and port 2 is M
                          nullAttach(4),  -- port 1 is M and port 2 is M
                          dualPrio(5)     -- dual attach priority mode
                              }
        MAX-ACCESS    read-write
        STATUS        current
        DESCRIPTION   "The requested concentrator attachment type. For a
                      dual attachment concentrator which can be
                      connected to the trunk ring, the first FDDI port
                      is configured as A and the second FDDI port is
                      configured as B.
                      For a single attachment concentrator which can be
                      connected beneath another concentrator, the first
                      FDDI port is configured as M and the second FDDI
                      port is configured as S. For a null attachment
                      concentrator which can be located at the root of
                      the tree, the first two FDDI ports are configured
                      as M.
                      This object does not take effect until the
                      concentrator is reset. The current attachment
                      type can be determined from snmpFddiPORTPCType
                      for ports 1 and 2."
        DEFVAL { dualAttach }
        ::= { systemGrp 7 }

sysTraffic OBJECT-TYPE
        SYNTAX        INTEGER (0..100)
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION   "Traffic meter value, i.e. the percentage of
                      bandwidth utilization for the previous polling
                      interval."
        ::= { systemGrp 8 }

sysReset OBJECT-TYPE
        SYNTAX        INTEGER {
                           other(1),       -- none of the following
                           reset(2),       -- resetting the system
                           resetMinDown(3) -- reset in minimal down time
                              }
        MAX-ACCESS    read-write
        STATUS        deprecated
        DESCRIPTION   "Writing reset(2) to this object resets the
                      control logic of all modules in the system.
                      Writing resetMinDown(3) to this object resets the
                      system with the minimal system down time. The
                      resetMinDown(3) is only supported in systems with
                      redundant supervisors.

                      This object is deprecated and replaced by
                      csyScheduledReset in CISCO-SYSTEM-MIB."
        ::= { systemGrp 9 }

sysBaudRate OBJECT-TYPE
        SYNTAX        INTEGER {
                                b600(600),
                                b1200(1200),
                                b2400(2400),
                                b4800(4800),
                                b9600(9600),
                                b19200(19200),
                                b38400(38400)
                                }
        MAX-ACCESS    read-write
        STATUS        current
        DESCRIPTION   "The baud rate in bits per second of the RS-232
                      port."
        DEFVAL { b9600 }
        ::= { systemGrp 10 }

sysInsertMode OBJECT-TYPE
        SYNTAX        INTEGER {
                                other(1),       -- none of the following
                                standard(2),    -- standard insertion
                                scheduled(3),   -- scheduled insertion
                                graceful(4)     -- graceful insertion
                                }
        MAX-ACCESS    read-write
        STATUS        current
        DESCRIPTION   "The mode for inserting M-ports into the
                       concentrator ring."
        ::= { systemGrp 11 }

sysClearMacTime OBJECT-TYPE
        SYNTAX        TimeTicks
        MAX-ACCESS    read-write
        STATUS        deprecated
        DESCRIPTION   "The time (in hundredths of a second) since mac
                      counters were last cleared. Writing a 0 to this
                      object causes the mac counters to be cleared."
        ::= { systemGrp 12 }

sysClearPortTime OBJECT-TYPE
        SYNTAX        TimeTicks
        MAX-ACCESS    read-write
        STATUS        deprecated
        DESCRIPTION   "The time (in hundredths of a second) since port
                      counters were last cleared. Writing a 0 to this
                      object causes the port counters to be cleared."
        ::= { systemGrp 13 }

-- the FDDI ring map table

sysFddiRingTable OBJECT-TYPE
        SYNTAX        SEQUENCE OF SysFddiRingEntry
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION   "The fddi ring map table. This table lists the
                      nodes in the FDDI ring(s) to which the system
                      belongs."
        ::= { systemGrp 14 }

sysFddiRingEntry OBJECT-TYPE
        SYNTAX        SysFddiRingEntry
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION   "A FDDI Ring table entry."
        INDEX         { sysFddiRingSMTIndex, sysFddiRingAddress }

share/mib/CISCO-STACK-MIB.my  view on Meta::CPAN

                      wsc65509(38),  -- 9 slot Chassis
                      cisco7613(40), -- 13 slot Chassis
                      wsc2948ggetx(41), -- closed 2 slot Switch
                      cisco7604(42), -- 4 slot Chassis
                      wsc6504e(43),  -- 4 slot Chassis
                      mec6524gs8s(45), -- closed 1 slot switch
                      mec6524gt8s(48), -- closed 1 slot switch
                      wsc6509ve(51),   -- 9 slot Chassis
                      cisco7603s(52)   -- 3 slot Chassis
                                }
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION   "The chassis system type."
        ::= { chassisGrp 1 }

chassisBkplType OBJECT-TYPE
        SYNTAX        INTEGER {
                                other(1),       -- none of the following
                                fddi(2),        -- FDDI
                                fddiEthernet(3),-- FDDI and Ethernet
                                giga(4),        -- 1.2 Gigabit switch
                                giga3(5),       -- 3.6 Gigabit switch
                                giga3E(6),      -- 3.6 Gigabit switch
                                                -- enhanced
                                giga12(7),      -- 12 Gigabit switch
                                giga16(8),      -- 16 Gigabit switch
                                giga40(9)        -- 40 Gigabit switch
                                }
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION   "The chassis backplane type."
        ::= { chassisGrp 2 }

chassisPs1Type OBJECT-TYPE
        SYNTAX        INTEGER {
                                other(1),       -- none of the following
                                none(2),        -- no power supply
                                w50(3),         -- 50 watt supply
                                w200(4),        -- 200 watt supply
                                w600(5),        -- 600 watt supply
                                w80(6),         -- 80 watt supply
                                w130(7),        -- 130 watt supply
                                wsc5008(8),     -- 376 watt supply
                                wsc5008a(9),    -- 376 watt supply w/PFC
                                w175(10),       -- 175 watt supply
                                wsc5068(11),    -- 376 watt supply DC
                                wsc5508(12),    -- 1100 watt supply
                                wsc5568(13),    -- 1200 watt supply DC
                                wsc5508a(14),   -- 1200 watt supply
                                w155(15),       -- 155 watt supply
                                w175pfc(16),    -- 175 watt supply w/PFC
                                w175dc(17),     -- 175 watt supply DC
                                wsc5008b(18),   -- 376 watt supply
                                                -- w/PFC, OCP
                                wsc5008c(19),   -- 436 watt supply w/PFC
                                wsc5068b(20),   -- 376 watt supply DC
                                                -- w/OCP
                                wscac1000(21),  -- 1000 watt supply AC
                                wscac1300(22),  -- 1300 watt supply AC
                                wscdc1000(23),  -- 1000 watt supply DC
                                wscdc1360(24),  -- 1360 watt supply DC
                                wsx4008(25),    -- 400 watt supply
                                wsc5518(26),    -- 805 watt supply AC
                                wsc5598(27),    -- 805 watt supply DC
                                w120(28),       -- 120 watt
                                externalPS(29), -- external power supply
                                wscac2500w(30), -- 2500 watt supply AC
                                wscdc2500w(31), -- 2500 watt supply DC
                                wsx4008dc(32),  -- 400 watt supply DC
                                wscac4000w(33), -- 4000 watt supply AC
                                pwr4000dc(34),  -- 4000 watt supply DC
                                pwr950ac(35),   -- 950 watt supply AC
                                pwr950dc(36),   -- 950 watt supply DC
                                pwr1900ac(37),  -- 1900 watt supply AC
                                pwr1900dc(38),  -- 1900 watt supply DC
                                pwr1900ac6(39), -- 1900 watt supply
                                                -- AC/6 slots
                                wsx4008ac650w(42), -- 650 watt supply AC
                                wsx4008dc650w(43), -- 650 watt supply DC
                                wscac3000w(44),   -- 3000 watt supply AC
                                pwrc451000ac(46), -- 1000 watt supply AC
                                pwrc452800acv(47),-- 2800 watt supply AC
                                pwrc451300acv(48),-- 1300 watt supply AC
                                pwrc451400dcp(49),-- 1400 watt supply DC
                                wscdc3000w(50),   -- 3000 watt supply DC
                                pwr1400ac(51),    -- 1400 watt supply AC
                                w156(52),         -- 156 watt supply AC
                                wscac6000w(53),   -- 6000 watt supply AC
                                pwr2700ac(54),    -- 2700 watt supply AC
                                pwr2700dc(55),    -- 2700 watt supply DC
                                wscac8700we(58),  -- 8700 watt supply AC
                                pwr2700ac4(59),   -- 2700 watt supply AC
                                pwr2700dc4(60),   -- 2700 watt supply DC
                                pwr400dc(63),     -- 400 watt supply DC
                                pwr400ac(64),     -- 400 watt supply AC
                                pwr6000dc(105),   -- 6000 watt supply DC
                                pwr1500dc(106)    -- 1500 watt supply DC
                                }
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION   "Type of power supply number 1."
        ::= { chassisGrp 3 }

chassisPs1Status OBJECT-TYPE
        SYNTAX        INTEGER {
                                other(1),       -- none of the following
                                ok(2),          -- status ok
                                minorFault(3),  -- minor problem
                                majorFault(4)   -- major problem
                                }
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION   "Status of power supply number 1. If the status is
                      not ok, the value of chassisPs1TestResult gives
                      more detailed information about the power supply's
                      failure condition(s)."
        ::= { chassisGrp 4 }

chassisPs1TestResult OBJECT-TYPE
        SYNTAX        INTEGER (0..65535)
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION   "Test result for power supply number 1. A zero
                      indicates that the supply passed all tests. Bits
                      set in the result indicate error conditions."
        ::= { chassisGrp 5 }

chassisPs2Type OBJECT-TYPE
        SYNTAX        INTEGER {
                                other(1),       -- none of the following
                                none(2),        -- no power supply
                                w50(3),         -- 50 watt supply
                                w200(4),        -- 200 watt supply
                                w600(5),        -- 600 watt supply
                                w80(6),         -- 80 watt supply
                                w130(7),        -- 130 watt supply
                                wsc5008(8),     -- 376 watt supply
                                wsc5008a(9),    -- 376 watt supply w/PFC
                                w175(10),       -- 175 watt supply
                                wsc5068(11),    -- 376 watt supply DC
                                wsc5508(12),    -- 1100 watt supply
                                wsc5568(13),    -- 1200 watt supply DC
                                wsc5508a(14),   -- 1200 watt supply
                                w155(15),       -- 155 watt supply
                                w175pfc(16),    -- 175 watt supply w/PFC
                                w175dc(17),     -- 175 watt supply DC
                                wsc5008b(18),   -- 376 watt supply
                                                -- w/PFC, OCP
                                wsc5008c(19),   -- 436 watt supply w/PFC
                                wsc5068b(20),   -- 376 watt supply DC
                                                -- w/OCP
                                wscac1000(21),  -- 1000 watt supply AC
                                wscac1300(22),  -- 1300 watt supply AC
                                wscdc1000(23),  -- 1000 watt supply DC
                                wscdc1360(24),  -- 1360 watt supply DC
                                wsx4008(25),    -- 400 watt supply
                                wsc5518(26),    -- 805 watt supply AC
                                wsc5598(27),    -- 805 watt supply DC
                                w120(28),       -- 120 watt
                                externalPS(29), -- external power supply
                                wscac2500w(30), -- 2500 watt supply AC
                                wscdc2500w(31), -- 2500 watt supply DC
                                wsx4008dc(32),  -- 400 watt supply DC
                                wscac4000w(33), -- 4000 watt supply AC
                                pwr4000dc(34),  -- 4000 watt supply DC
                                pwr950ac(35),   -- 950 watt supply AC
                                pwr950dc(36),   -- 950 watt supply DC
                                pwr1900ac(37),  -- 1900 watt supply AC
                                pwr1900dc(38),  -- 1900 watt supply DC
                                pwr1900ac6(39), -- 1900 watt supply
                                                -- AC/6 slots
                                wsx4008ac650w(42), -- 650 watt supply AC
                                wsx4008dc650w(43), -- 650 watt supply DC
                                wscac3000w(44),   -- 3000 watt supply AC
                                pwrc451000ac(46), -- 1000 watt supply AC
                                pwrc452800acv(47),-- 2800 watt supply AC
                                pwrc451300acv(48),-- 1300 watt supply AC
                                pwrc451400dcp(49),-- 1400 watt supply DC
                                wscdc3000w(50),   -- 3000 watt supply DC
                                pwr1400ac(51),    -- 1400 watt supply AC
                                w156(52),         -- 156 watt supply AC
                                wscac6000w(53),   -- 6000 watt supply AC
                                pwr2700ac(54),    -- 2700 watt supply AC
                                pwr2700dc(55),    -- 2700 watt supply DC
                                wscac8700we(58),  -- 8700 watt supply AC
                                pwr2700ac4(59),   -- 2700 watt supply AC
                                pwr2700dc4(60),   -- 2700 watt supply DC
                                pwr400dc(63),     -- 400 watt supply DC
                                pwr400ac(64),     -- 400 watt supply AC
                                pwr6000dc(105),   -- 6000 watt supply DC
                                pwr1500dc(106)    -- 1500 watt supply DC
                                }
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION   "Type of power supply number 2."
        ::= { chassisGrp 6 }

chassisPs2Status OBJECT-TYPE
        SYNTAX        INTEGER {
                                other(1),       -- none of the following
                                ok(2),          -- status ok
                                minorFault(3),  -- minor problem
                                majorFault(4)   -- major problem
                                }
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION   "Status of power supply number 2. If the status is
                      not ok, the value of chassisPs2TestResult gives
                      more detailed information about the power supply's
                      failure condition(s)."
        ::= { chassisGrp 7 }

chassisPs2TestResult OBJECT-TYPE
        SYNTAX        INTEGER (0..65535)
        MAX-ACCESS    read-only



( run in 0.945 second using v1.01-cache-2.11-cpan-5735350b133 )