view release on metacpan or search on metacpan
share/mib/CISCO-STACK-MIB.my view on Meta::CPAN
Deprecate the following objects: sysIpAddr, sysNetMask,
sysBroadcast, sysTrapReceiverTable, sysReset,
sysClearPortTime, sysClearMacTime,
sysPortFastBpduGuard, chassisComponentTable,
portSpantreeFastStart, vlanTable, portChannelTable.
Remove the TC MacAddressType, and replaced other uses
by MacAddress."
REVISION
"200209240000Z"
DESCRIPTION
"Added more HW models."
REVISION
"200106110000Z"
DESCRIPTION
"Added cat6000 new HW chassis & modules."
REVISION
"200104110000Z"
DESCRIPTION
"Added more HW modules;
share/mib/CISCO-STACK-MIB.my view on Meta::CPAN
redundant supervisors.
This object is deprecated and replaced by
csyScheduledReset in CISCO-SYSTEM-MIB."
::= { systemGrp 9 }
sysBaudRate OBJECT-TYPE
SYNTAX INTEGER {
b600(600),
b1200(1200),
b2400(2400),
b4800(4800),
b9600(9600),
b19200(19200),
b38400(38400)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The baud rate in bits per second of the RS-232
port."
DEFVAL { b9600 }
share/mib/CISCO-STACK-MIB.my view on Meta::CPAN
w175pfc(16), -- 175 watt supply w/PFC
w175dc(17), -- 175 watt supply DC
wsc5008b(18), -- 376 watt supply
-- w/PFC, OCP
wsc5008c(19), -- 436 watt supply w/PFC
wsc5068b(20), -- 376 watt supply DC
-- w/OCP
wscac1000(21), -- 1000 watt supply AC
wscac1300(22), -- 1300 watt supply AC
wscdc1000(23), -- 1000 watt supply DC
wscdc1360(24), -- 1360 watt supply DC
wsx4008(25), -- 400 watt supply
wsc5518(26), -- 805 watt supply AC
wsc5598(27), -- 805 watt supply DC
w120(28), -- 120 watt
externalPS(29), -- external power supply
wscac2500w(30), -- 2500 watt supply AC
wscdc2500w(31), -- 2500 watt supply DC
wsx4008dc(32), -- 400 watt supply DC
wscac4000w(33), -- 4000 watt supply AC
pwr4000dc(34), -- 4000 watt supply DC
share/mib/CISCO-STACK-MIB.my view on Meta::CPAN
w175pfc(16), -- 175 watt supply w/PFC
w175dc(17), -- 175 watt supply DC
wsc5008b(18), -- 376 watt supply
-- w/PFC, OCP
wsc5008c(19), -- 436 watt supply w/PFC
wsc5068b(20), -- 376 watt supply DC
-- w/OCP
wscac1000(21), -- 1000 watt supply AC
wscac1300(22), -- 1300 watt supply AC
wscdc1000(23), -- 1000 watt supply DC
wscdc1360(24), -- 1360 watt supply DC
wsx4008(25), -- 400 watt supply
wsc5518(26), -- 805 watt supply AC
wsc5598(27), -- 805 watt supply DC
w120(28), -- 120 watt
externalPS(29), -- external power supply
wscac2500w(30), -- 2500 watt supply AC
wscdc2500w(31), -- 2500 watt supply DC
wsx4008dc(32), -- 400 watt supply DC
wscac4000w(33), -- 4000 watt supply AC
pwr4000dc(34), -- 4000 watt supply DC
share/mib/CISCO-TC.my view on Meta::CPAN
invalidEncapsulation,
modemLineDeasserted,
ipSecHndshkInProgress,
sfpEthCompliantErr,
cellularModemUnattached,
outOfGlblRxBuffers,
sfpFcCompliantErr,
ethIntfNotLicensed,
domainIdsInvalid,
fabricNameInvalid."
REVISION "201002240000Z"
DESCRIPTION
"Added CiscoURLStringOrEmpty textual convention."
REVISION "200906180000Z"
DESCRIPTION
"Added the new textual convention CiscoVrfName"
REVISION "200903100000Z"
DESCRIPTION
"Added the new textual convention CiscoInterfaceIndexList"
REVISION "200902260000Z"
DESCRIPTION
share/mib/CISCO-TC.my view on Meta::CPAN
CiscoPbbServiceIdentifier"
REVISION "200607060000Z"
DESCRIPTION
"Added the following enums to IfOperStatusReason:
- elpFailureAllZeroPeerWWNRcvd,
- preferredPathIsolation."
REVISION "200604130000Z"
DESCRIPTION
"Added enumeration to IfOperStatusReason from 113-131
('dpvmVsanSuspended' to 'domainOther')."
REVISION "200506240000Z"
DESCRIPTION
"Added CvE164Address textual convention."
REVISION "200506160000Z"
DESCRIPTION
"Added following textual conventions:
CiscoURLString
CiscoHTTPResponseStatusCode
EntLogicalIndexOrZero."
REVISION "200410110000Z"
DESCRIPTION
share/mib/CISCO-VTP-MIB.my view on Meta::CPAN
"Added support for encapsulation type notApplicable"
REVISION "9805191130Z"
DESCRIPTION
"Added support for encapsulation type negotiation"
REVISION "9708081138Z"
DESCRIPTION
"Added Backup CRF object"
REVISION "9705091130Z"
DESCRIPTION
"Added ARE and STE hop counts."
REVISION "9702241115Z"
DESCRIPTION
"Added support for turning on VTP for Trunk cards."
REVISION "9701271730Z"
DESCRIPTION
"Added support for version 2 features."
REVISION "9609161230Z"
DESCRIPTION
"Updated the Token-Ring support."
REVISION "9607171230Z"
DESCRIPTION
share/mib/FOUNDRY-SN-AGENT-MIB.mib view on Meta::CPAN
fpgaPbifOc(14),
fpgaStatsOc(15),
fpgaXppOc(16),
fpgaPbifMrj(17),
fpgaStatsMrj(18),
fpgaXppMrj(19),
fpgaPbifSp2(20),
fpgaXgmacSp2(21),
fpgaXppSp2(22),
fpgaPbif8x10(23),
fpgaXpp8x10(24),
fpgaXpp2x100(25),
fpgaPbifMetro(26)
}
-- Groups
snChasGen OBJECT IDENTIFIER ::= { snChassis 1 }
snChasPwr OBJECT IDENTIFIER ::= { snChassis 2 }
snChasFan OBJECT IDENTIFIER ::= { snChassis 3 }
snChasUnit OBJECT IDENTIFIER ::= { snChassis 4 }
share/mib/FOUNDRY-SN-AGENT-MIB.mib view on Meta::CPAN
FI_SLAVE_FIBER_4G 0x1A
FI_SLAVE_FIBER_8G 0x1B
FI_SLAVE_COPPER_8G 0x1C
FI_MASTER_COPPER_8G 0x1D
POS_155M2P 0x1E
FI_MASTER_COPPER_4G 0x1F
FI_MASTER_COPPER_2G 0x20
MASTER_COPPER_4G 0x21
MASTER_COPPER_2G 0x22
MASTER_M4_8G 0x23
MASTER_M4_4G 0x24
MASTER_M4_2G 0x25
MASTER_M4_0G 0x26
MASTER_M5_0G 0x27
POS_2488M 0x28
SLAVE_M5_0G 0x29
POS_N2488M 0x2A
STACK_IPC_48_2 0x2B
SLAVE_NPA_FIBER_4G 0x2C
ATM_2PORT 0x2D
ATM_4PORT 0x2E
share/mib/FOUNDRY-SN-AGENT-MIB.mib view on Meta::CPAN
FI_SLAVE_FIBER_4G 0x1A
FI_SLAVE_FIBER_8G 0x1B
FI_SLAVE_COPPER_8G 0x1C
FI_MASTER_COPPER_8G 0x1D
POS_155M2P 0x1E
FI_MASTER_COPPER_4G 0x1F
FI_MASTER_COPPER_2G 0x20
MASTER_COPPER_4G 0x21
MASTER_COPPER_2G 0x22
MASTER_M4_8G 0x23
MASTER_M4_4G 0x24
MASTER_M4_2G 0x25
MASTER_M4_0G 0x26
MASTER_M5_0G 0x27
POS_2488M 0x28
SLAVE_M5_0G 0x29
POS_N2488M 0x2A
STACK_IPC_48_2 0x2B
SLAVE_NPA_FIBER_4G 0x2C
ATM_2PORT 0x2D
ATM_4PORT 0x2E
share/mib/FOUNDRY-SN-AGENT-MIB.mib view on Meta::CPAN
FI_SLAVE_FIBER_4G 0x1A
FI_SLAVE_FIBER_8G 0x1B
FI_SLAVE_COPPER_8G 0x1C
FI_MASTER_COPPER_8G 0x1D
POS_155M2P 0x1E
FI_MASTER_COPPER_4G 0x1F
FI_MASTER_COPPER_2G 0x20
MASTER_COPPER_4G 0x21
MASTER_COPPER_2G 0x22
MASTER_M4_8G 0x23
MASTER_M4_4G 0x24
MASTER_M4_2G 0x25
MASTER_M4_0G 0x26
MASTER_M5_0G 0x27
POS_2488M 0x28
SLAVE_M5_0G 0x29
POS_N2488M 0x2A
STACK_IPC_48_2 0x2B
SLAVE_NPA_FIBER_4G 0x2C
ATM_2PORT 0x2D
ATM_4PORT 0x2E
share/mib/FOUNDRY-SN-AGENT-MIB.mib view on Meta::CPAN
fdryFws48PortCopperBaseModule(2225),
fdryFws24GPortCopperBaseModule(2226),
fdryFws48GPortCopperBaseModule(2227),
--Modules for FCX family
fdryFcx624BaseModule(2208),
fdryFcx648BaseModule(2209),
fdryFcxSfpPlus4Port10gModule(2220),
--Modules for ICX6610 family
fdryIcx6610624BaseModule(2240),
fdryIcx6610648BaseModule(2241),
fdryIcx6610624PoeBaseModule(2244),
fdryIcx6610648PoeBaseModule(2245),
fdryIcx6610624FBaseModule(2246),
fdryIcx6610DualMode8PortModule(2248),
fdryIcx6610Qsfp10Port160gModule(2249),
--Modules for ICX6430 family
fdryIcx6430624BaseModule(2016),
fdryIcx6430648BaseModule(2017),
fdryIcx6430624PoeBaseModule(2020),
fdryIcx6430648PoeBaseModule(2021),
fdryIcx6430sfp4Port4gModule(2024),
--Modules for ICX6450 family
fdryIcx6450624BaseModule(2032),
fdryIcx6450648BaseModule(2033),
fdryIcx6450624PoeBaseModule(2036),
fdryIcx6450648PoeBaseModule(2037),
fdryIcx6450sfp4Port40gModule(2040)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Configured Module Type."
::= { snAgentConfigModuleEntry 2 }
share/mib/FOUNDRY-SN-AGENT-MIB.mib view on Meta::CPAN
-- Modules for FWS family
fdryFws24PortCopperBaseModule(2224),
fdryFws48PortCopperBaseModule(2225),
fdryFws24GPortCopperBaseModule(2226),
fdryFws48GPortCopperBaseModule(2227),
--Modules for FCX family
fdryFcx624BaseModule(2208),
fdryFcx648BaseModule(2209),
fdryFcxSfpPlus4Port10gModule(2220),
--Modules for ICX6610 family
fdryIcx6610624BaseModule(2240),
fdryIcx6610648BaseModule(2241),
fdryIcx6610624PoeBaseModule(2244),
fdryIcx6610648PoeBaseModule(2245),
fdryIcx6610624FBaseModule(2246),
fdryIcx6610DualMode8PortModule(2248),
fdryIcx6610Qsfp10Port160gModule(2249),
--Modules for ICX6430 family
fdryIcx6430624BaseModule(2016),
fdryIcx6430648BaseModule(2017),
fdryIcx6430624PoeBaseModule(2020),
fdryIcx6430648PoeBaseModule(2021),
fdryIcx6430sfp4Port4gModule(2024),
--Modules for ICX6450 family
fdryIcx6450624BaseModule(2032),
fdryIcx6450648BaseModule(2033),
fdryIcx6450624PoeBaseModule(2036),
fdryIcx6450648PoeBaseModule(2037),
fdryIcx6450sfp4Port40gModule(2040)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Configured Module Type."
::= { snAgentConfigModule2Entry 3 }
share/mib/FOUNDRY-SN-ROOT-MIB.mib view on Meta::CPAN
snICX661048HPOERouter OBJECT IDENTIFIER ::= { snICX661048HPOE 3 } -- ICX661048-HPOE Base Router
snICX661048HPOEPRouter OBJECT IDENTIFIER ::= { snICX661048HPOE 4 } -- ICX661048-HPOE Premium Router
snICX661048HPOEARouter OBJECT IDENTIFIER ::= { snICX661048HPOE 5 } -- ICX661048-HPOE Advanced Router
--FastIron CX 6430 (ICX6430) family
snICX6430Family OBJECT IDENTIFIER ::= { registration 57} -- FastIron CX 6430 series family
snICX643024Family OBJECT IDENTIFIER ::= { snICX6430Family 1 }
snICX643024BaseFamily OBJECT IDENTIFIER ::= { snICX643024Family 1 }
snICX643024 OBJECT IDENTIFIER ::= { snICX643024BaseFamily 1 } -- ICX6430 24-port 10/100/1G w/4x1G
snICX643024Switch OBJECT IDENTIFIER ::= { snICX643024 1 } -- ICX643024 switch
snICX643024HPOEFamily OBJECT IDENTIFIER ::= { snICX643024Family 2 }
snICX643024HPOE OBJECT IDENTIFIER ::= { snICX643024HPOEFamily 1 } -- ICX6430 24-port HPOE 10/100/1G w/4x1G
snICX643024HPOESwitch OBJECT IDENTIFIER ::= { snICX643024HPOE 1 } -- ICX643024-HPOE switch
snICX643048Family OBJECT IDENTIFIER ::= { snICX6430Family 2 }
snICX643048BaseFamily OBJECT IDENTIFIER ::= { snICX643048Family 1 }
snICX643048 OBJECT IDENTIFIER ::= { snICX643048BaseFamily 1 } -- ICX6430 48-port 10/100/1G w/4x1G
snICX643048Switch OBJECT IDENTIFIER ::= { snICX643048 1 } -- ICX643048 switch
snICX643048HPOEFamily OBJECT IDENTIFIER ::= { snICX643048Family 2 }
snICX643048HPOE OBJECT IDENTIFIER ::= { snICX643048HPOEFamily 1 } -- ICX6430 48-port HPOE 10/100/1G w/4x1G
snICX643048HPOESwitch OBJECT IDENTIFIER ::= { snICX643048HPOE 1 } -- ICX643048-HPOE switch
--FastIron CX 6450 (ICX6450) family
snICX6450Family OBJECT IDENTIFIER ::= { registration 58} -- FastIron CX 6450 series family
snICX645024Family OBJECT IDENTIFIER ::= { snICX6450Family 1 }
snICX645024BaseFamily OBJECT IDENTIFIER ::= { snICX645024Family 1 }
snICX645024 OBJECT IDENTIFIER ::= { snICX645024BaseFamily 1 } -- ICX6450 24-port 10/100/1G w/4x1/10G
snICX645024Switch OBJECT IDENTIFIER ::= { snICX645024 1 } -- ICX645024 switch
snICX645024BaseL3Router OBJECT IDENTIFIER ::= { snICX645024 2 } -- ICX645024 Base L3 router
snICX645024Router OBJECT IDENTIFIER ::= { snICX645024 3 } -- ICX645024 Base Router
snICX645024PRouter OBJECT IDENTIFIER ::= { snICX645024 4 } -- ICX645024 Premium Router
snICX645024HPOEFamily OBJECT IDENTIFIER ::= { snICX645024Family 2 }
snICX645024HPOE OBJECT IDENTIFIER ::= { snICX645024HPOEFamily 1 } --ICX6450 24-port HPOE 10/100/1G w/4x1/10G
snICX645024HPOESwitch OBJECT IDENTIFIER ::= { snICX645024HPOE 1 } -- ICX645024-HPOE switch
snICX645024HPOEBaseL3Router OBJECT IDENTIFIER ::= { snICX645024HPOE 2 } -- ICX645024-HPOE Base L3 router
snICX645024HPOERouter OBJECT IDENTIFIER ::= { snICX645024HPOE 3 } -- ICX645024-HPOE Base Router
snICX645024HPOEPRouter OBJECT IDENTIFIER ::= { snICX645024HPOE 4 } -- ICX645024-HPOE Premium Router
snICX645048Family OBJECT IDENTIFIER ::= { snICX6450Family 2 }
snICX645048BaseFamily OBJECT IDENTIFIER ::= { snICX645048Family 1 }
snICX645048 OBJECT IDENTIFIER ::= { snICX645048BaseFamily 1 } -- ICX6450 48-port 10/100/1G w/4x1/10G
snICX645048Switch OBJECT IDENTIFIER ::= { snICX645048 1 } -- ICX645048 switch
share/mib/FOUNDRY-SN-SWITCH-GROUP-MIB.mib view on Meta::CPAN
gmtPlus0900(14),
gmtPlus0800(15),
gmtPlus0700(16),
gmtPlus0600(17),
gmtPlus0500(18),
gmtPlus0400(19),
gmtPlus0300(20),
gmtPlus0200(21),
gmtPlus0100(22),
gmt(23),
gmtMinus0100(24),
gmtMinus0200(25),
gmtMinus0300(26),
gmtMinus0400(27),
gmtMinus0500(28),
gmtMinus0600(29),
gmtMinus0700(30),
gmtMinus0800(31),
gmtMinus0900(32),
gmtMinus1000(33),
gmtMinus1100(34),
share/mib/RMON2-MIB.txt view on Meta::CPAN
serialModemConnectResp OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"An ASCII string containing substrings that describe the
expected modem connection response code and associated bps
rate. The substrings are delimited by the first character
in the string, for example:
/CONNECT/300/CONNECT 1200/1200/CONNECT 2400/2400/
CONNECT 4800/4800/CONNECT 9600/9600
will be interpreted as:
response code bps rate
CONNECT 300
CONNECT 1200 1200
CONNECT 2400 2400
CONNECT 4800 4800
CONNECT 9600 9600
The agent will use the information in this string to adjust
the bps rate of this serial interface once a modem connection
is established.
A value that is appropriate for a wide variety of modems is:
'/CONNECT/300/CONNECT 1200/1200/CONNECT 2400/2400/
CONNECT 4800/4800/CONNECT 9600/9600/CONNECT 14400/14400/
CONNECT 19200/19200/CONNECT 38400/38400/'."
::= { serialConfigEntry 6 }
serialModemNoConnectResp OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"An ASCII string containing response codes that may be